Alarm & power-fail tests: what SIRE 2.0 inspectors ask and find

Inspectors ask to see power-failure tests for bridge equipment and compare the dates with the planned maintenance system.

Do this before the inspector arrives: Run ECDIS UPS, VDR, BNWAS and nav lights power-fail tests.

What the inspector wants to see

Questions inspectors ask about Alarm & power-fail tests

Why should BNWAS not be left in 'auto' mode?
Per MSC.128(75), auto mode activates BNWAS only when autopilot/track control is in use; it is inhibited the rest of the time.
Which BNWAS tests are expected before departure?
2nd and 3rd stage alarms, dormant period, and emergency power - stages 1-3 tested on both main and secondary power, with records.
What is the BNWAS dormant period, and how do the alarm stages follow?
Dormant period 3-12 min. Then 15 s to 2nd stage, then 90 s to 3rd stage (up to 3 min on large ships). Stages 2 and 3 may be combined except on passenger ships.
What timing accuracy is required for BNWAS, and who may change its mode?
5% or 5 s, whichever is less. Mode and dormant period controls should be security protected, Master only.
Do you have a risk assessment for managing AMS alarms?
Inspectors asked for one.
If a machinery alarm is not acknowledged, when must the engineers' alarm sound?
Within 5 minutes. A new alarm while the first is still active must also be announced.

There are 11 Alarm & power-fail tests questions in NilObs, with spaced repetition so the ones you miss come back. Practise them free.

Real Alarm & power-fail tests observations, and how to avoid them

From 3 de-identified observations in SIRE 2.0, CDI and pre-vetting reports from 2025 and 2026. Wording paraphrased; ship, crew and company names removed.

Operator procedure required only the BNWAS power failure alarm test, not a check of all three alarm stages on the secondary power supply.
Avoid it: When testing power changeover, confirm the BNWAS runs through all alarm stages on secondary supply.
SIRE 2.0 · Chapter 4 Navigation & communications · Process observation

Who answers for Alarm & power-fail tests

Second Officer, Chief Engineer, Second Engineer, Electro-Technical Officer. NilObs picks the questions and the daily drill for your role.

Rehearse Alarm & power-fail tests before your next inspection.
A 5-minute daily drill for your role, an AI inspector that grades your answers, and live industry updates. Free to start.
Start free

Other topics

ECDIS9 observationsRadar4 observationsUKC3 observationsPassage planning5 observationsGMDSS10 observationsEquipment tests vs PMS23 observationsDocuments & SMS51 observationsRest hours & drills17 observationsDefect reporting29 observationsWatchkeeping16 observationsSteering2 observationsLSA & FFA31 observationsEngine room50 observationsCargo69 observationsPIQ accuracy46 observationsPermits & RA11 observationsEmergency equipment43 observationsGas testing & enclosed space61 observationsPPE & personal safety21 observationsPollution prevention27 observationsSecurity & cyber11 observationsTraining & certificates25 observationsHull & condition31 observationsMooring & access59 observations